Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 206 items found.

  • PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module

    781369-01 - NI

    204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.

  • PXIe-4357 , 20-Channel, 24-Bit PXI Temperature Input Module

    782118-01 - NI

    20-Channel, 24-Bit PXI Temperature Input Module—The NI PXIe‑4357 input module provides integrated data acquisition and signal conditioning for 2‑, 3‑, or 4‑wire resistance temperature detector (RTD) measurements. It offers both high-speed and high-resolution modes. It provides per channel software-programmable configurations and automatically scale measured data into engineering units.

  • PXIe-4300, 16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module

    781337-01 - NI

    16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module—The PXIe‑4300 provides integrated data acquisition and signal conditioning for high-voltage measurements. It provides increased accuracy, simultaneous sampling, and synchronization features for scalable measurement systems. The PXIe‑4300 includes 300 Vrms channel‑to‑channel CAT II isolation and 3,300 Vrms channel‑to‑earth 5 second withstand isolation to protect users and equipment from hazardous voltages. This module offers programmable lowpass filtering, DC input coupling, and two PFI lines for digital input triggering. The included NI‑DAQmx driver simplifies hardware and configuration and measurement.

  • PXIe-4310, 16-Bit, 8-Channel, 400 kS/s/ch, Ch-Ch Isolated PXI Analog Input Module

    784813-01 - NI

    16-Bit, 8-Channel, 400 kS/s/ch, Ch-Ch Isolated PXI Analog Input Module—The PXIe-4310 is a channel-to-channel isolated, filtered analog input module for higher voltage measurements. The module offers the ability to select an analog filter per channel to provide extra filtering performance. You also can operate up to four different input ranges per terminal block and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI-DAQmx driver simplifies hardware configuration and measurement.

  • PCIe to cPCI Bridge

    Kontron

    3U/ 4HP CompactPCI remote controller for use in CompactPCI rear system slot inside a 19″ chassis, PC PCIe interface card for standard desktop PC, allows control of CompactPCI Chassis from desktop PC

  • NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module

    783731-01 - NI

    200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.

  • PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module

    781345-01 - NI

    102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.

  • SHC68-C68-S, 68 pin VHDCI to 68 pin VHDCI, 0.5m

    186380-0R5 - NI

    SHC68-C68-S, 68 pin VHDCI to 68 pin VHDCI, 0.5m

  • SHC68-C68-S, 68 pin VHDCI to 68 pin VHDCI, 2m

    186380-02 - NI

    SHC68-C68-S, 68 pin VHDCI to 68 pin VHDCI, 2m

  • Multifunction I/O

    PXI-2204 - ADLINK Technology Inc.

    ADLINIK PXI-2204, PXI-2205, and PXI-2206 are high-density, high-performance multifunction PXI modules. These devices can sample up to 64 AI channels with various gain settings and scan sequences---making them ideal for high-density analog signals with various input ranges and sampling speeds. These devices also offer a differential mode for 32 AI channels to achieve maximum noise elimination. The PXI-2200 series also features analog and digital triggering, 2-CH 12-bit analog outputs with waveform generation capabilities, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timers/counters.PXI-220464-CH 12-Bit 3 MS/s Multi-Function PXI Module

  • Multifunction I/O

    PXI-2206 - ADLINK Technology Inc.

    ADLINIK PXI-2204, PXI-2205, and PXI-2206 are high-density, high-performance multifunction PXI modules. These devices can sample up to 64 AI channels with various gain settings and scan sequences---making them ideal for high-density analog signals with various input ranges and sampling speeds. These devices also offer a differential mode for 32 AI channels to achieve maximum noise elimination. The PXI-2200 series also features analog and digital triggering, 2-CH 12-bit analog outputs with waveform generation capabilities, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timers/counters.

  • Multifunction I/O

    PXI-2205 - ADLINK Technology Inc.

    ADLINIK PXI-2204, PXI-2205, and PXI-2206 are high-density, high-performance multifunction PXI modules. These devices can sample up to 64 AI channels with various gain settings and scan sequences---making them ideal for high-density analog signals with various input ranges and sampling speeds. These devices also offer a differential mode for 32 AI channels to achieve maximum noise elimination. The PXI-2200 series also features analog and digital triggering, 2-CH 12-bit analog outputs with waveform generation capabilities, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timers/counters.PXI-220564-CH 16-Bit 500 kS/s Multi-Function PXI Module

  • Multifunction I/O

    PXI-2005 - ADLINK Technology Inc.

    ADLINIK PXI-2010, PXI-2005 and PXI-2006 are simultaneous-sampling multifunction PXI modules to meet a wide range of application requirements. These products can simultaneously sample 4 AI channels with differential input configurations to achieve maximum noise elimination. They also provide 2-CH 12-bit analog outputs with waveform generation capabilities, which can be performed together with analog input functions. If more analog input or output channels are required, multiple modules can be synchronized through the PXI trigger bus. This makes the PXI-2000 series ideal for stimulus/response tests. The PXI-2000 series also feature analog and digital triggering, 24-CH programmable digital I/O lines, and 2- CH 16-bit general-purpose timer/counters. The auto-calibration feature adjusts the gain and offset to a specified accuracy, eliminating the need to calibrate the modules by adjusting trimpots.

  • Multifunction I/O

    PXI-2010 - ADLINK Technology Inc.

    ADLINIK PXI-2010, PXI-2005 and PXI-2006 are simultaneous-sampling multifunction PXI modules to meet a wide range of application requirements. These products can simultaneously sample 4 AI channels with differential input configurations to achieve maximum noise elimination. They also provide 2-CH 12-bit analog outputs with waveform generation capabilities, which can be performed together with analog input functions. If more analog input or output channels are required, multiple modules can be synchronized through the PXI trigger bus. This makes the PXI-2000 series ideal for stimulus/response tests. The PXI-2000 series also feature analog and digital triggering, 24-CH programmable digital I/O lines, and 2- CH 16-bit general-purpose timer/counters. The auto-calibration feature adjusts the gain and offset to a specified accuracy, eliminating the need to calibrate the modules by adjusting trimpots.

  • Multifunction I/O

    PXI-2006 - ADLINK Technology Inc.

    ADLINIK PXI-2010, PXI-2005 and PXI-2006 are simultaneous-sampling multifunction PXI modules to meet a wide range of application requirements. These products can simultaneously sample 4 AI channels with differential input configurations to achieve maximum noise elimination. They also provide 2-CH 12-bit analog outputs with waveform generation capabilities, which can be performed together with analog input functions. If more analog input or output channels are required, multiple modules can be synchronized through the PXI trigger bus. This makes the PXI-2000 series ideal for stimulus/response tests. The PXI-2000 series also feature analog and digital triggering, 24-CH programmable digital I/O lines, and 2- CH 16-bit general-purpose timer/counters. The auto-calibration feature adjusts the gain and offset to a specified accuracy, eliminating the need to calibrate the modules by adjusting trimpots.

Get Help